OVATIOTMDR

Dual Chamber, model number 6550

OVATIO DR

 

Compact Intelligence

  • Size: 29cc, world's smallest ICD3

  • Output: 34J

  • Features:

 

 Superior specificity

 

  99.9%1 intrinsic conduction

 

OVATIOTM DR™ can detect and treat the full spectrum of tachyarrhythmias with painless antitachycardia pacing (ATP). OVATIO DR™ offers ICD recipients the comfort of painless therapy, which may significantly improve their quality of life by terminating the slowest (100 bpm) as well as fastest (up to 255 bpm) ventricular tachyarrhythmias.

Its main features include AAIsafeR and PARAD+. SafeR is a pacing mode that monitors AV conduction and promotes natural heart function by limiting unnecessary stimulation of the right ventricle. With its unique arrhythmia discrimination criterion, PARAD+ protects patients against inappropriate shocks, which may be delivered in response to misclassified supraventricular tachyarrhythmias.

OVATIO DR™ is the smallest dual-chamber ICD currently available (29 cc).

Essential for patients who need more energy to terminate life-threatening arrhythmias, OVATIO DR™ offers 34 J of maximum output. OVATIO DR™ is also optimally shaped and durable, offering ease of implantation and long-term patient comfort.

 

 

 

AIDA

Enhanced follow-ups

  • Intuitive navigation system

  • Shorter interrogation time

  • Short-cuts

  • Pre-programmed settings

 

 

AIDA+, clinic time focused on quality

  • Automatic diagnosis and data interpretation

  • Proposed programming solutions

  • Comprehensive, day-by-day data storage and retrieval capability

 

 

Example: What type of AV block occurred?

Dual chamber EGM and markers.
Switch to DDD due to 2nd degree AV Block

Example: Did AV conduction change over time?
Day-by-day, 6-month data

Click here for a better view

 

Example: Which type of arrhythmias and therapies did the patient experience?

 

Click here for a better view

 

Intended uses, warnings and precautions

 


1. 99% overall specificity with "out-of-the box settings". Hintringer F et al: Comparison of the specificity of implantable dual chamber defibrillator detection algorithms. PACE 2004;27:976-982.

2. Unique long cycle search criteria is used to avoid treating AF that is rapidly conducted to the ventricle, and thus limits inappropriate therapies for AF to 0.3% to 0.8% risk per patient. Mletzko R et al: Enhanced Specificity of a Dual Chamber ICD Arrhythmia Detection Algorithm by Rate Stability criteria. PACE 2004;27:1113-1119.

3. Based on September 2007 data